Atomic Force Microscopy Topography, force curves, and phase images. Ana Viana anaviana@ciencias.ulisboa.pt |
|
Automatic Solution Crystallization Reactor Solubility, metastable zone width and kinetics of crystallization. Carlos Bernanrdes cebernardes@ciencias.ulisboa.pt |
|
Automatic Tensiometer Study of surface and interfacial tension between 280K and 335K. Maria Soledade Santos mssantos@ciencias.ulisboa.pt |
|
Capillary Electrophoresis with Diode Array Detector Determination of ionic compounds. JMF Nogueira jmnogueira@ciencias.ulisboa.pt |
|
Calvet-Drop Microcalorimeter Enthalpies of vaporization and sublimation, heat capacities of solids or liquids. ME Minas da Piedade mepiedade@ciencias.ulisboa.pt |
|
Contact Angle Goniometer Evaluation of the wettability of surfaces. Jorge Correia jorge.correia@ciencias.ulisboa.pt |
|
Density and Sound Velocity Meter Density and sound speed measurements of solutions. Angela Filomena Simões dos Santos afsantos@ciencias.ulisboa.pt |
|
Differential Scanning Calorimeter Study of thermal transitions of solids and liquids; Thermal characterization of polymers, such as glass transition temperature, crystallization temperature and melting point. Maria José Vitoriano Lourenço mjlourenco@ciencias.ulisboa.pt |
|
Differential Scanning Calorimeter Characterization of solid-solid phase transitions, glass transition, crystallization and fusion. Manuel E. Minas da Piedade mepiedade@ciencias.ulisboa.pt |
|
FTIR Spectrometer Enables infrared spectroscopy in transmission mode, operating between 25000-50 cm-1. Reflection spectra can be obtained by ATR, specular and diffuse reflection. Luís Santos luis.santos@tecnico.ulisboa.pt |
|
Imaging Ellipsometer Study of the optical properties and thickness of thin films. Jorge Correia jorge.correia@ciencias.ulisboa.pt |
|
LKB Flow Microcalorimeter Energetics of Cell Metabolism; Enthalpies of Mixture and Dilution; Energetics and Kinetics of Slow Reactions. Manuel E. Minas da Piedade mepiedade@ciencias.ulisboa.pt |
|
Metricon M-Line Spectrometer Measurement of the thickness and the refractive index of dielectric and polymer films and bulk samples, using optical waveguiding techniques. Luís Santos luis.santos@tecnico.ulisboa.pt |
|
Potentiostat/Galvanostat (AUTOLAB) Investigation of reaction mechanisms related to redox chemistry. Determination of metal ions and certain organic species in aqueous solutions. Cristina Oliveira cmoliveira@ciencias.ulisboa.pt |
|
Precision Solution Calorimeter Determination of enthalpies of solution of solids and liquids in liquids. Filomena Martins filomena.martins@ciencias.ulisboa.pt |
|
Probe Beam Deflection Measurement of mass flows at interfaces. Jorge Correia jorge.correia@ciencias.ulisboa.pt |
|
Raman Spectrometer Micro-Raman spectrometer with UV-VIS-NIR optics, an achromatic spectrograph with 800 mm focal length equipped with two gratings, a CCD detector and 532, 633 and 785 nm excitation lasers, for point analysis and mapping. Luís Santos luis.santos@tecnico.ulisboa.pt |
|
Rheometer Viscosity measurements. Fernando J. V. Santos fjsantos@ciencias.ulisboa.pt |
|
Scanning Electrochemical Microscopy Determination of local electrochemical activity. Jorge Correia jorge.correia@ciencias.ulisboa.pt |
|
Stopped-Flow Spectrometer Study of fast reactions in solution. Filomena Martins filomena.martins@ciencias.ulisboa.pt |
|
Thermogravimetric Analyser Thermal decomposition and desolvation of materials. Manuel E. Minas da Piedade mepiedade@ciencias.ulisboa.pt |
|
CW X-band EPR Spectrometer Bruker ESP 300E João Paulo Telo jptelo@tecnico.ulisboa.pt |
|
TG-DSC analyser, TGA 92 (Setaram) Acquisition of sample mass change and heat flow profiles as a function of temperature increasing, in inert or oxidative atmosphere, from RT up to 1600 ºC; Determination of maximum organic compounds (e.g. toluene) adsorption capacity (breakthrough curves). M. Filipa Ribeirofilipa.ribeiro@tecnico.ulisboa.pt |
|
TG-DSC analyser, Setsys Evo 16 (Setaram) Acquisition of sample mass change and heat flow profiles as a function of temperature increasing, in inert or oxidative atmosphere, from RT up to 1600 ºC; Determination of maximum organic compounds (e.g. toluene) adsorption capacity (breakthrough curves). M. Filipa Ribeiro filipa.ribeiro@tecnico.ulisboa.pt |
|
DSC analyser Thermal transitions of solids and liquids; Thermal characterization of polymers, such as glass transition temperature, crystallization temperature and melting point. M. Filipa Ribeiro filipa.ribeiro@tecnico.ulisboa.pt |
|
Gases physisorption and chemisorption analyser, ASAP 2010 (Micromeritics) Gas isotherm acquisition (adsorption-desorption), namely nitrogen at 77 K, and subsequent determination of specific surface area, porous volume, pores size distribution (methods BJH, DFT, etc.); Possibility of using Ar as adsorptive gas. M. Filipa Ribeiro filipa.ribeiro@tecnico.ulisboa.pt |
|
Gases sorption analyser, Autosorb-IQ-MP (Quantachrom) Gas isotherm acquisition (adsorption-desorption), namely nitrogen at 77 K, and subsequent determination of specific surface area, porous volume, pores size distribution (methods BJH, DFT, etc.); Possibility of using Ar as adsorptive gas. M. Filipa Ribeiro filipa.ribeiro@tecnico.ulisboa.pt |
|
Temperature programmed reduction/oxidation/desorption analyser, Autochem II 2920 (Micromeritics) Determination of TPR, TPO and TPD quantitative profiles as a function of temperature, from RT up to 1000 ºC; Determination of metal dispersion and metallic surface area by the means of H2 chemisorption (dynamic-pulses method). M. Filipa Ribeiro filipa.ribeiro@tecnico.ulisboa.pt |
|
Jobin-Yvon Variable Angle Spectroscopic Ellipsometer Luis Santos luis.santos@tecnico.ulisboa.pt |
|
Graphite furnace atomic absorption spectrometer with Zeeman effect correction Margarida Romão mcsantos@tecnico.ulisboa.pt |
|
Particle sizing and counting analyzer Rute Domingues rute.domingues@tecnico.ulisboa.pt |
|
Potentiostat Margarida Romão mcsantos@tecnico.ulisboa.pt |
|
Microscopes Fernanda Carvalho |
|
Dynamic Chemisorption Analyzer Micromeritics ChemiSorb 2720 Coupled with a TPx System; Characterization of materials/catalysts: superficial area, TPR, TPO and TPD analysis Joaquim Branco |
|
Two assemblies to work in continuous at atmospheric pressure Includes an Agilent 7280D with FID and a HP-PLOT U GC capillary column and an Agilent 4890D GC with TCD and a Restek ShinCarbon ST column Joaquim Branco |
|
Assembly to work in continuous under pressure (1-150 bar) Includes a GC: Shimadzu 9A with TCD coupled to a Restek ShinCarbon ST column and FID coupled to a Supelco 10% SP 2100 column Joaquim Branco |
|
Viscometer SV-10 Working in the range 0.3 to 10 0000 mPa.s João Paulo Leal |
|
Conductivity meter BANTE – DOS 120W João Paulo Leal |
|
Inert atmosphere glovebox To work with oxygen and moisture sensitive coordination and organometallic compounds, particularly of thorium and uranium; the glovebox is also a protection against contamination of workers by these radioactive metals. Leonor Maria |